145
Programme unit
ERROR, I/O COMMUNICATION Y
ERROR, LOW OIL LEVEL Y
ERROR, LOW OR HIGH VOLTAGE Y
ERROR, ERROR CODES FROM MOTOR Y
ERROR, PRESS SENSOR TILT Y
ERROR, PRESSURE SENSOR TIMEOUT Y
ERROR, DOOR SWITCH TILT Y
ERROR, LEVEL OFFSET Y
ERROR, LEVEL SYSTEM NOT CALIB. Y
TIME DELAY BEFORE DOOR OPENING 0:30
UPPER TEMPERATURE FOR ERROR 98°C
LOWERTEMPERATUREFORERROR -9°C
MAX ADJUST TEMPERATURE 97°C
MAXIMUM EXTRACT SPEED 1200
DEFAULT WASH SPEED 48
DISTRIBUTION SPEED 90
ERROR, I/O COMMUNICATION Y
ERROR, LOW OIL LEVEL Y
ERROR, LOW OR HIGH VOLTAGE Y
ERROR, ERROR CODES FROM MOTOR Y
ERROR, PRESS SENSOR TILT Y
ERROR, PRESSURE SENSOR TIMEOUT Y
ERROR, DOOR SWITCH TILT Y
ERROR, LEVEL OFFSET Y
ERROR, LEVEL SYSTEM NOT CALIB. Y
TIME DELAY BEFORE DOOR OPENING 0:30
UPPER TEMPERATURE FOR ERROR 98°C
LOWERTEMPERATUREFORERROR -9°C
MAX ADJUST TEMPERATURE 97°C
MAXIMUM EXTRACT SPEED 1200
DEFAULT WASH SPEED 48
DISTRIBUTION SPEED 90
Upper limit for manual temperature
adjustment (”Max adjust temperature”)
Here you determine the highest temperature the
user may alter the wash temperature to manually
(by using to move to the line for
”SET TEMPERATURE” then entering a new wash
temperature).
PROGRAM STEP: MAIN WASH 1
STEP TIME: 720 SEC
SET TEMPERATURE: 85 °C
ACTUAL TEMPERATURE: 21 °C
REMAINING TIME: 70 MIN
DRUM SPEED: 48 RPM
RAPID ADVANCE
PAUSE
SELECT
991 NORMAL 95°C
The function above will be available only if the
answer Y (Yes) is in place for these two functions:
• ADJUSTTEMPERATURE(SETTINGS1)which
determines whether or not it will be allowed to
alter the temperature during a program.
• TEMPERATUREINCREASEALLOWED(SET-
TINGS 2) which determines whether or not it will
be allowed to alter the temperature parameter
to higher than the original temperature in the
wash program or not.
Maximum extract speed
Here you determine the machine’s maximum ex-
traction speed.
This speed cannot be exceeded, neither by pro-
gramming parameters in wash programs nor by
manual adjustment.
Use the numeric keys to
enter the value.
If you make a mistake while
entering digits:
Press ERASE.
When you have finished:
Press .
Use the numeric keys to
enter the value.
If you make a mistake while
entering digits:
Press ERASE.
When you have finished:
Press .