English
HMI
Run
LOC
1800rpm
00:00
1800
3.5
60.0
rpm
A
Hz
Run
LOC
1800rpm
00:00
2000
0
64.0s
Motor Speed Estimated Value
Run
LOC
1800rpm
00:00
0.0
rpm
0.0
A
0.0
V
00.0
Hz
00.0
V
00.0
%
0.0
kW
0
◦
C
00.0
%
Figure4.4:Defaultmainscreens
Toaccessthemenus,justpressthe”Enter”key.
4.2MENUACCESSMODE-MENULEVELS
Whenyoupressthe”Enter”keyonamainscreen,youaccessthemenus.Inthemenus,itispossibletonavigate
thegroupsandsubgroupstoaccessthevariables.
Eachvariablehasitsowncoding,containingitslocationinthemenustructureanditsidentification.Digitsare
separatedbyaperiod.
Example:
C2.1.4=Motorratedvoltagevalue
C2.1.4=Configurations–>Motor–>MotorData–>RatedVoltage
Level1Level2Level3Level4Edition
CC2C2.1C2.1.4
ConfigurationsMotorMotorDataRatedVoltage440V
4.2.1ReadingVariables-StatusandDiagnosticsMenus
AllreadingvariablesfortheHMIareavailableintwomainmenus:StatusandDiagnostics.
StatusMenu:Ithasreadingvariableswithupdatedvalues:current,voltageandothers.
Ready
LOC
0rpm
00:00
0.0
0.0
0
rpm
A
Hz
Ready
LOC
0rpm
00:00
Main Menu
Status
Diagnostics
Configurations
Assistants
Ready
LOC
0rpm
00:00
Status
1. Inverter
2. Measurements
3. I/Os
4. Functional Safety
5. Communications
Ready
LOC
0rpm
00:00
S2 Measurements
1. Motor Speed
2. Motor Torque
3. Inverter Output
4. Motor temperatures
5. Inverter temperatures
Ready
LOC
0rpm
00:00
S2.2 Motor Torque
1. Estimated Value
0.0%
Ready
LOC
0rpm
00:00
Motor Torque
S2.2.2 Estimated Value
0.0 %
Figure4.5:Averagetorquereading
DiagnosticsMenu:Ithasreadingvariableswithvaluessavedasaresultofevents: actuationofprotections,
alarms,startandothers.
CFW900|49