EasyManua.ls Logo

Weiler E1650 - Distance Control Interlock Tests; Elevator and Conveyor Floor Plates Inspection

Weiler E1650
174 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
WEILER E1650 REMIXING TRANSFER VEHICLE
5-24
Maintenance
5
Maintenance Procedures
Distance Control Interlock - Park Brake Test
1. Start machine.
2. Ensure park brake is engaged.
3. Push Distance-From-Paver Button (1). Machine
must not move. The following screen must appear
on electronic display.
Contact a Weiler dealer if distance control interlock
does not function properly.
Distance Control Interlock - Speed Test
1. Cycle Propel 3-Speed Button to transport position.
2. Push Distance-From-Paver Button. Distance control
must not start. The following screen must appear on
electronic display.
Contact a Weiler dealer if distance control interlock
does not function correctly.
Elevator / Conveyor Floor Plates - Inspect
Check elevator and conveyor floor liner plates for wear and replace when worn to a thickness of
0.13” (3mm).
1
Message
Turn Parking
Brake Off To
Activate Distance
Control
Exit
Distance Control Setup
Move Gear Selection Out
of High Speed For
Distance Control
Exit