EasyManua.ls Logo

Weiler E1650 - Fuel System Maintenance

Weiler E1650
174 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WEILER E1650 REMIXING TRANSFER VEHICLE
5-27
Maintenance
5
Maintenance Procedures
Fuel Filter / Water Separator - Drain
NOTICE: The water separator (1) should be monitored
daily for signs of water. If water is present, drain the
water from the bowl. The engine should never be
allowed to run with water separator more than half full
of water. Engine damage may result.
1. Open drain valve and allow fluid to drain into a
suitable container.
2. Close drain valve. Dispose of drained fluid in
accordance with local regulations and mandates.
NOTICE: The water separator is under suction during
normal engine operation. Ensure that drain valve is
tightened securely to prevent air from entering fuel system.
Fuel Tank - Fill
1. Fill fuel tank at fill cap (1) at end of each day to
reduce condensation. Do not overfill; leave room for
expansion.
NOTICE: Refer to Engine Operation and Maintenance
Manual for fuel requirements.
Fuel Level is shown on electronic display panel.
WARNING
Petroleum-based fluids leaked or spilled onto hot surfaces or electrical
components can explode or burn.
Turn ignition switch off when servicing machine. Clean up fluid spills
immediately. No flame. No smoking.
WARNING
Fuel and fumes can explode and burn.
Stop engine and remove ignition key before refueling. No flame. No
smoking.
1
1

Related product manuals