Maintenance Procedures
Overall Machine - Check
Shields/Guards and Barriers - Check that all shields, guards and barriers are installed and are
fastened securely to machine. Replace and repair any shields, guards or barriers that are damaged or
have missing parts.
Hardware - Check machine for loose, worn, or missing parts and hardware. Tighten any loose parts
and replace any worn or missing parts. Refer to Parts Manual for replacement parts.
Frame - Check machine frame and contact Weiler dealer immediately if you notice any bending or
cracking.
Fire Prevention - Keep engine compartment, battery, hydraulic lines, fuel tank and operator’s
station clean of accumulated grease and debris.
Electrical Harness - Check that electrical harness and all wires are properly supported and not
rubbing on any sharp corners. Support any loose wires hanging under machine frame.
Engine Belts - Inspect for worn, cracked, or frayed belts. Replace if worn or damaged.
Pump Drive Gearbox - Drain / Refill
1. Clean area around pump drive breather/fill
fitting (1).
2. Remove breather/fill fitting (1).
3. Remove drain plug (2) and drain oil into a container
with a capacity of at least 6 qt (5.7 L).
4. Replace drain plug.
5. Refill gearbox through breather/fill port (1) with 6
quarts (5.7 L) of oil.
6. Check oil level with dipstick (3).
NOTICE: Do not over fill.
7. Wash breather in clean nonflammable solvent.
8. Allow breather to dry or use compressed air to dry.
9. Install breather/fill fitting.