At
high speed running
with
overload
When
an
overload is applied to the engine running
at
a high speed, the centrifugal force of
ball weights become small
as
the speed
is
reduced, and fork lever 2
is
pulled rightward by
governor springs 1 and
2,
increasing fuel injection. Fork lever 2 becomes ineffective to
increase
fuel injection when it is stopped by maximum output limit bolt. After that when the
force of spring becomes
larger than the centrifugal force of ball weights, fork lever 1 moves
rightward to increase
fuel injection, driving the engine continuously with a high torque.
At
high
speed
running with overload
1.
Ball Weight
2. Fork Lever 2
3.
Governor Spring 1
4.
Governor Spring 2
5.
Maximum Output
Limit
Bolt
6.
Spring
7.
Fork Lever 1
To
stop
engine
When stop
lever is moved
to
"STOP" position, fork lever
is
moved leftward and then control
rack is moved
to
the non-injection position, stopping the engine.
To
stop
engine
1.
Stop Lever
2. Fork Lever 1
3.
Control Rack
49