4-15
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Open the washer top (See page 4-3).
4. The transformer for the UIC is attached to
the control panel bracket, at the right end
near the CCU.
5. Disconnect the wire harness connector from
the transformer to the CCU and cut wire tie.
6. Remove two 1/4” hex head screws that
secure the transformer to the control panel
bracket and remove the transformer.
9. There are four tabs on each side of the
chemical dispenser that secure the top of
the dispenser to the base. Remove the
top to access the water inlet holes in order
to clean any mineral or detergent build-up,
which could slow the incoming water.
Arrow On
Flanged End
Arrow
On Tub
Hot Valve
Number 1
Upper
Cold Valve
Number 2
Lower
Cold Valve
Number 3
Bleach
Fabric
Softener
Detergent
View Of Under Side Of
Chemical Dispenser Top
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
UIC TRANSFORMER
NOTE: Remove and replace rubber screw
tip covers and wire tie when servicing
transformer.
UIC Transformer
On Other Side
Transformer Primary
Winding Connector
CCU
Wire Tie
Placement
Rubber
Screw Tip
Covers