Technical Data
WWaallll OOvveennss
6-2
Technical Data Chart
Part Description
Voltage Ohms
Part Number
Motorized Latch
Temperature Sensor
Oven Light
Element, Convection
Element, Convection
Fan, Convection CCW
Fan, Convection CW
Element, Bake Outer
Element, Bake Inner
Element, Bake Outer
Element, Bake Inner
Upper Cooling Fan
Lower Cooling Fan
Temperature Probe
Element, Bake Stone
Element, Bake Stone
Transformer
Element, Broil 30”
Element, Broil 30”
Element, Broil 36”
Element, Broil 36”
120
12
240
208
120
120
240
240
208
208
120
120
240
208
120 to 12
240
208
240
208
2900
1091 @ 75°F
.6
22.80 to 26.39
22.80 to 26.39
8.8
8.8
33.16 to 36.64
29.58 to 32.69
33.16 to 36.64
29.58 to 32.69
HI 9.7 / LO 12.8
HI 7.8 / LO 10.0
34,000 @ 90°F
15.68 to 17.14
15.68 to 18.14
16
15.19 to 17.59
15.19 to 17.59
15.84 to 13.67
13.67 to 15.84
4
20
2182 to 2526
1638 to 1897
55
55
1572 to 1737
1762 to 1947
1180.75 to 1304.68
1323.46 to 1462.41
65
80
3174 to 3673
2384.03 to 2758.83
3600
3273 to 3790
2458.39 to 2846.71
3636 to 4211
2731.04 to 3162.93
800263
800306
800307
800341
800345
800350
800360
801143
800529
800717
800950
801120
Amperage Watts
9.09 to 10.52
7.87 to 9.12
6.55 to 7.23
7.34 to 8.11
5.67 to 6.27
6.36 to 7.03
13.22 to 15.30
11.46 to 13.26
13.63 to 15.79
11.81 to 13.68
15.15 to 17.54
13.13 to 15.20
Ohm Testing Elements at Relay Board
This procedure will allow the service technician to ohm any of the elements directly at the relay board.
At the relay board, pull the wire off of the terminal DLB/E11. This is done to keep from ohming the relay board. It
does not take the High Limit out of the equation, but if the technician DOES NOT get an ohm reading from the DLB
lead to all of the element leads, then, there is a problem with the High Limit.
To eliminate the High Limit when taking ohm readings, the MDL cover will need to be removed. Then, remove the
wire from High Limit switch that goes to the elements. Now, take the ohm reading from that wire at the High Limit to
the desired element wire at the relay board.
Right Convection Element: PR5/E5 to DLB/E11 wire
Left Convection Element: PR2/E5 to DLB/E11 wire
Outer Bake Element: PR4/E8 to DLB/E11 wire
Inner Bake Element: PR3/E6 to DLB/E11 wire
Bake Stone Element: PR6/E10 to DLB/E11 wire
Broil Element: PR1/E4 to DLB/E11 wire