3) Consumption Power
4) Power Cord Length: 1830 +/- 50mm
5) Power Cord Switch: Exist
6) Feature
- Withstand Resistance: 100 or more (at DC 500V)
- Insulating revisiting pressure: Must be no problem within 1 min. (at1000Vac,10mA)
- Leaking Current: under 3.5mA
- Running Current: under 40A PEAK (AT 25 °C (77 °F), COLDSTART)
under 50A PEAK (In other conditions)
- Rising Time: within 2Sec
- FallingTime: over 20ms
- Surge: Ring Wave 6KV-500A (Normal, Common)
7) Environment Condition
- Operating temperature range: 0 °C ~ 40 °C (32 °F ~ 104 °F)
- Maintaining temperature range: -20 °C ~ 40 °C (68 °F ~ 104 °F)
- Preserving Humidity Condition: 10% ~ 90% RH
- Operating atmospheric pressure range: 1atm
8) EMI Requirement: CISPR, FCC, CE, MIC,
9) Safety Requirement: IEC950 UL1950, CSA950, C-UL, Semko, EK, CB, CCC(CCIB),GOST,
EPA,
HVPS Board
The HVPS board creates the high voltage of THV/MHV/Supply/Dev and supplies them to the de-
velopment system for making best quality printing image. The HVPS part takes the 24V and out-
puts the high voltage such as THV/MHV/Supply/Dev, and the outputted high voltage is supplied
to the toner, OPC cartridge, and transfer roller.
(a) Transfer High Voltage (THV+)
- Input Voltage: 24 V DC +15% / -10% (21.6V~27.6V)
- Out Voltage: +1300KV 1.5% (200 Load)
- Out Voltage Trigger: 6.5
- Input Voltage Variation: 5%
Load Variation: 5%
- Out Voltage Rising Time: 100 ms Max
- Out Voltage Falling Time: 100 ms Max
Table 3:
NO Items CH1(+5V) CH2(24V) System
1 Stand-By 0.6 A 1.3 A AVG: 65Wh
2 Printing 0.8 A 1.9 A AVG: 350Wh
3 Sleep-Mode 0.5 A 0.3 A AVG: 10Wh