Image Quality
3-12 11/05 Workcentre PE 220
IQ 11 Ghost (3)
Description
White ghost occurs in the black image printing at 47.5mm intervals.
IQ 12 Ghost (4)
Description
Ghost occurs at 47.5mm(or 63.9mm) intervals.
Check and Cause Solution
1. The life of the developer may be
expired.
1. Install a new print cartridge, PL 1.
2. Possible abnormal voltage and
bad contact of the terminal of the
supply roller in the print cartridge.
2. Install a new print cartridge, PL 1
.
Check and Cause Solution
1. The temperature of the fuser is
too high because the thermistor is
contaminated.
CAUTION
Take care not to bend or break the
thermistor.
1. Clean the heat roll, pressure roll
and thermistor, PL 7
. If necessary
install a new fuser, PL 1
.