xiC - Technical Manual Version 1.16
19
xiC Digital Input / Output (GPIO) Interface and 3.11 External power supply input (AUX).
Power supply, via Digital Input / Output (GPIO) Interface connector:
5 V (nominal)
4.45 V to 5.5 V (at the camera connector)
3.2. General Specification
3.2.1. Environment
Description
Symbol
Value
Optimal ambient temperature operation
T
opt
+10 to +25 °C
Ambient temperature operation
T
max
+0 to +50 °C
Ambient temperature for storage and transportation
T
storage
-30 to +60 °C
Relative Humidity, non-condensing
RH
80 %
table 3-1, environment
Housing temperature must not exceed +65°C. It is recommended to mount the camera on heat conductive structure to
improve heat dissipation. The following parameters are not guaranteed if the camera is operated outside the optimum range:
Dark current
Dynamic Range
Linearity
Acquisition and readout noise
S/N ratio, durability
Please refer to chapter 3.12 Heat Dissipation.
3.2.2. Firmware / Host driver / API features
Description
Value
Interpolation methods
Proprietary
White balance coefficients ranges
0.0 to 3.9
Sharpness filter
-400 to 400 %
Gamma
0.3 to 1.0
Full color correction matrix (3+1)x3 coefficients ranges
-3.9 to 3.9
table 3-2, firmware / API features
More details on API/SDK features are available at XIMEA support pages: https://www.ximea.com/support/wiki/apis/APIs