11.3 List of Parameters
11-25
11
Appendix
Parameter
No.
Name Setting Range Unit
Factory
Setting
Setting
Validation
Pn50C Input Signal Selections 3
−−8888 After restart
0
1
2
3
4
5
6
7
8
9
A
B
ON when CN1-40 input signal is ON (L-level).
ON when CN1-41 input signal is ON (L-level).
ON when CN1-42 input signal is ON (L-level).
ON when CN1-43 input signal is ON (L-level).
ON when CN1-44 input signal is ON (L-level).
ON when CN1-45 input signal is ON (L-level).
ON when CN1-46 input signal is ON (L-level).
Sets signal ON.
Sets signal OFF.
ON when CN1-40 input signal is OFF (H-level).
ON when CN1-41 input signal is OFF (H-level).
ON when CN1-42 input signal is OFF (H-level).
ON when CN1-43 input signal is OFF (H-level).
0 to F
Same as /SPD-D
0 to F
Same as /SPD-D
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
ON when CN1-44 input signal is OFF (H-level).
ON when CN1-45 input signal is OFF (H-level).
ON when CN1-46 input signal is OFF (H-level).
C
D
E
F
0 to F
Same as /SPD-D
/SPD-D Signal Mapping
/SPD-A Signal Mapping
/SPD-B Signal Mapping
/C-SEL Signal Mapping (Control mode change when ON (L-level))
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for YASKAWA E-II Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA E-II Series and is the answer not in the manual?

YASKAWA E-II Series Specifications

General IconGeneral
BrandYASKAWA
ModelE-II Series
CategoryServo Drives
LanguageEnglish

Related product manuals