EasyManua.ls Logo

YASKAWA E-II Series - Page 328

YASKAWA E-II Series
341 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.3 List of Parameters
11-25
11
Appendix
Parameter
No.
Name Setting Range Unit
Factory
Setting
Setting
Validation
Pn50C Input Signal Selections 3
−−8888 After restart
0
1
2
3
4
5
6
7
8
9
A
B
ON when CN1-40 input signal is ON (L-level).
ON when CN1-41 input signal is ON (L-level).
ON when CN1-42 input signal is ON (L-level).
ON when CN1-43 input signal is ON (L-level).
ON when CN1-44 input signal is ON (L-level).
ON when CN1-45 input signal is ON (L-level).
ON when CN1-46 input signal is ON (L-level).
Sets signal ON.
Sets signal OFF.
ON when CN1-40 input signal is OFF (H-level).
ON when CN1-41 input signal is OFF (H-level).
ON when CN1-42 input signal is OFF (H-level).
ON when CN1-43 input signal is OFF (H-level).
0 to F
Same as /SPD-D
0 to F
Same as /SPD-D
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
ON when CN1-44 input signal is OFF (H-level).
ON when CN1-45 input signal is OFF (H-level).
ON when CN1-46 input signal is OFF (H-level).
C
D
E
F
0 to F
Same as /SPD-D
/SPD-D Signal Mapping
/SPD-A Signal Mapping
/SPD-B Signal Mapping
/C-SEL Signal Mapping (Control mode change when ON (L-level))