Peripheral Devices E - 2
Branch Short Circuit Protection
Select fuses and MCCB based on NEC Table 430-152 and the data provided.
Table E.1 208-240Vac Input
Model
CIMR-E7U
Rated Input
Amps
Rated Output
Amps
Fuse Selection Criteria MCCB Selection Criteria
Minimum Voltage
Rating (Vac)
Maximum I
2
t
Melt Rating
Circuit Breaker
Type
Minimum Voltage
Rating (Vac)
Minimum MCCB
Amp Rating
20P4 4.3 3.6 250 17 Inverse Time 240 7
20P7 5.5 4.6 250 17 Inverse Time 240 7
21P5 9.4 7.8 250 27 Inverse Time 240 15
22P2 13 10.8 250 60 Inverse Time 240 30
23P7 20 16.8 250 200 Inverse Time 240 30
25P5 24 23 250 276 Inverse Time 240 30
27P5 37 31 250 560 Inverse Time 240 50
2011 53 46.2 250 810 Inverse Time 240 100
2015 70 59.4 250 1570 Inverse Time 240 100
2018 89 74.8 250 2260 Inverse Time 240 150
2022 98 88 250 2260 Inverse Time 240 150
2030 120 115 250 4010 Inverse Time 240 150
2037 180 162 250 7320 Inverse Time 240 250
2045 212 192 250 9630 Inverse Time 240 400
2055 237 215 250 16000 Inverse Time 240 400
2075 350 312 250 31000 Inverse Time 240 600
2090
2110