6.2 208 V Narrow Model Specifications
158 YASKAWA TOEPYAIH6B01A HV600 AC Drive Narrow Bypass Installation & Startup
*1 The maximum applicable motor output is based on 4-pole, general-purpose 220 V motor ratings. The rated output current of the drive
output amps must be equal to or more than the motor rated current.
*2 The maximum applicable motor output complies with 208 V motor ratings as specified in NEC Table 430.250. The rated output current of
the drive output amps must be equal to or more than the motor rated current.
*3 Carrier frequency is 5 kHz. You must derate the current to increase the carrier frequency.