4-20
* 1. The setting is given for 200 V Class Inverters. Double the voltage for 400 V Class Inverters.
* 2. The factory setting for 400V 132kW and 220kW flax vector control (A1-02 = 3) is 1.5 kHz, for software version VSG123032 or later.
Open-loop
vector 2
control
(A1-02 = 4)
ASR switching fre-
quency (C5-07)
Switching the ASR
proportional gain and
integral time accord-
ing to the output fre-
quency
0.0 Hz
0.0 to max.
output fre-
quency
Set the output frequency at
which to change the ASR
proportional gain and inte-
gral time when the same val-
ues cannot be used for both
high-speed and low-speed
operation.
ASR primary delay
time (C5-06)
• Controlling hunting
and vibration
0.010 s
0.04 to
0.020 s
Increase the setting if
machine rigidity is low and
the system vibrates easily.
(Enabled in the range 0 to
35 Hz. Refer to Procedure
for Increasing the Speed
Response below.)
0.035 s
0.010 to
0.035 s
ASR primary delay
time 2 (C5-10)
• Controlling hunting
and vibration
0.010 s
0.010 to
0.035 s
Increase the setting if
machine rigidity is low and
the system vibrates easily.
(Enabled above 35 Hz. Refer
to Procedure for Increasing
the Speed Response below.)
Integral time of speed
estimator (N4-07)
• Speed response
• Controlling hunting
and vibration
0.030 ms
0.015 to
0.060 ms
(Enabled below the N4-11
setting.)
• Reduce the setting if speed
response is slow. (Typi-
cally, reduce in intervals of
0.05. Refer to Procedure
for Increasing the Speed
Response below.)
• Increase the setting if hunt-
ing or vibration occurs.
High-speed propor-
tional gain of speed
estimator (N4-10)
• Speed response
• Controlling hunting
and vibration
15 10 to 60
(Enabled below the N4-11
setting.)
• Increase the setting if
speed response is slow.
(Typically, increase in
intervals of 5. Refer to
Procedure for Increasing
the Speed Response
below.)
• Reduce the setting if hunt-
ing or vibration occurs.
Carrier frequency
selection (C6-11)
• Reducing motor
magnetic noise
• Controlling hunting
and vibration at low
speeds (3 Hz or less)
Depends
on the
capacity.
Default
value
• Increase the setting if
motor magnetic noise is
high.
• Reduce the setting if hunt-
ing or vibration occurs at
low to mi
ddle-range
speeds.
Table 4.4 Adjusted User Constants (Continued)
Control
Method
Name (Constant
Number)
Performance
Factory
Setting
Recom-
mended
Setting
Adjustment Method

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA varispeed G7 CIMR-G7B series and is the answer not in the manual?

YASKAWA varispeed G7 CIMR-G7B series Specifications

General IconGeneral
BrandYASKAWA
Modelvarispeed G7 CIMR-G7B series
CategoryInverter
LanguageEnglish

Related product manuals