EasyManua.ls Logo

YASKAWA varispeed G7 CIMR-G7B series

YASKAWA varispeed G7 CIMR-G7B series
495 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Constant Tables
5-21
C: Autotuning Constants
The following settings are made with the autotuning constants (C constants): Acceleration/deceleration times,
s-curve characteristics, slip compensation, torque compensation, speed control, and carrier frequency func-
tions.
Acceleration/Deceleration: C1
User constants for acceleration and deceleration times are shown in the following table.
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
C1-01
Accelera-
tion time 1
Sets the acceleration time to
accelerate from 0 to the maxi-
mum output frequency, in 1-
second units.
0.0 to
6000.0
*
10.0 s
Yes Q Q Q Q Q 200H
4-5
4-21
6-18
加速时间 1
C1-02
Decelera-
tion time 1
Sets the deceleration time to
decelerate from the maximum
output frequency to 0, in 1-
second units.
Yes Q Q Q Q Q 201H
4-5
4-21
6-18
减速时间 1
C1-03
Accelera-
tion time 2
The acceleration time when
the multi-function input
“accel/decel time 1” is set to
ON.
Yes A A A A A 202H
4-21
6-18
加速时间 2
C1-04
Decelera-
tion time 2
The deceleration time when
the multi-function input
“accel/decel time 1” is set to
ON.
Yes A A A A A 203H
4-21
6-18
减速时间 2
C1-05
Accelera-
tion time 3
The acceleration time when
the multi-function input
“accel/decel time 2” is set to
ON.
No A A A A A 204H
4-21
6-18
加速时间 3
C1-06
Decelera-
tion time 3
The deceleration time when
the multi-function input
“accel/decel time 2” is set to
ON.
No A A A A A 205H
4-21
6-18
减速时间 3
C1-07
Accelera-
tion time 4
The acceleration time when
the multi-function input
“accel/decel time 1” and
“accel/decel time 2” are set to
ON.
No A A A A A 206H
4-21
6-18
加速时间 4
C1-08
Decelera-
tion time 4
The deceleration time when
the multi-function input
“accel/decel time 1” and
“accel/decel time 2” are set to
ON.
No A A A A A 207H
4-21
6-18
减速时间 4
C1-09
Emergency
stop time
The deceleration time when
the multi-function input
“Emergency (fast) stop” is set
to ON.
This function can be used as a
stopping method when a fault
has been detected.
No A A A A A 208H
4-21
6-17
紧急停止时间

Table of Contents

Related product manuals