5-86
Factory Settings that Change with the Control Method (A1-02)
The factory settings of the following user constants will change if the control method (A1-02) is changed.
Con-
stant
Number
Name
Setting Range Unit
Factory Setting
Display
V/f
Control
V/f with
PG
Open-
loop
Vector
1
Flux
Vector
Open
Loop
Vector
2
b3-01
Speed search selection
0 to 3 1 232-2
起动速度搜索
b3-02
Speed search operating current
0 to 200 1% 120 - 100 - 10
速度搜索电流
b8-02
Energy-saving gain
0.0 to 10.0 0.1 - - 0.7 1.0 0.7
节能增益
b8-03
Energy-saving filter time constant
0.0 to 10.00 0.01 s - - 0.50 0.01 0.50
节能滤波 时间
C3-01
Slip compensation gain
0.0 to 2.5 0.1 0.0 - 1.0 1.0 1.0
滑差补偿增益
C3-02
Slip compensation primary delay time
0 to 10000 1 ms 2000 - 200 - -
滑差补偿时间
C4-02
Torque compensation primary delay time
constant
0 to 10000 1 ms
200
*5
200
*5
20 - -
转矩补偿延迟时间
C5-01
ASR proportional (P) gain 1
0.00 to 300.00 0.01 - 0.20 - 20.00 10.00
比例增益 1
C5-02
ASR integral (I) time
0.000 to 10.000 0.001 s - 0.200 - 0.500 0.500
积分时间 1
C5-03
ASR proportional (P) gain 2
0.00 to 300.00 0.01 - 0.02 - 20.00 10.00
比例增益 2
C5-04
ASR integral (I) time 2
0.000 to 10.000
0.001
sec.
- 0.050 - 0.500 0.500
积分时间 2
C5-06
ASR primary delay time
0.000 to 0.500 0.001 - - - 0.004 0.035
ASR 延迟时间
C6-02
Carrier frequency selection
1 to F
*6
-
6
*7
6
*7
6
*7
1
*7
1
*7
载波频率选择
d5-02
Torque reference delay time
0 to 1000 1 ms - - - 0 10
转矩控制延迟时间
E1-04
E3-02
Max. output frequency (FMAX)
0.0 to 400.0
*4
0.1 Hz
50.0
*3
50.0
*3
50.0 50.0 50.0
最高输出频率
E1-05
E3-03
Max. voltage (VMAX)
0.0 to 255.0 0.1 V
200.0
*3
200.0
*3
200.0 200.0 200.0
最大电压
E1-06
E3-04
Base frequency (FA)
0.0 to 400.0 0.1 Hz
50.0
*3
50.0
*3
50.0 50.0 50.0
基本频率
E1-07
E3-05
Mid. output frequency (FB)
0.0 to 400.0 0.1 Hz
2.5
*3
2.5
*3
3.0 0.0 0.0
中间频率