6-40
Normally, there is no need to make this setting. Adjust the constant as shown below.
If the motor is vibrating, increase the set value.
If the motor response is low, decrease the set value.
Hunting-prevention Function
The hunting-prevention function suppresses hunting when the motor is operating with a light load. This func-
tion can be used in V/f and V/f with PG.
Related Constants
* The factory setting depends upon the Inverter capacity. The value for a 200 v Class Inverter of 0.4 kW is given.
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vec-
tor
Open
Loop
Vector
2
N1-01
Hunting-pre-
vention func-
tion selection
0: Hunting-prevention function
disabled
1: Hunting-prevention function
enabled
The hunting-prevention function
suppresses hunting when the
motor is operating with a light
load.
This function is enabled in V/f
control method only.
If high response is to be given pri-
ority over vibration suppression,
disable the hunting-prevention
function.
0 or 1 1 No A A No No No 580H
防止失调功能
选择
N1-02
Hunting-pre-
vention gain
Set the hunting-prevention gain
multiplication factor.
Normally, there is no need to
make this setting.
Make the adjustments as follows:
If vibration occurs with light
load, increase the setting.
If the motor stalls, reduce the
setting.
If the setting is too large, the volt-
age will be too suppressed and the
motor may stall.
0.00 to
2.50
1.00 No A A No No No 581H
防止失调增益
N1-03
Hunting-pre-
vention time
constant
Set the hunting-prevention pri-
mary delay time in units of ms.
0 to
500
10 ms
*
No A A No No No 582H
防止失调时间