User Constant Tables
5-45
H: Terminal Function Constants
The following settings are made with the terminal function constants (H constants): Settings for external ter-
minal functions.
Multi-function Contact Inputs: H1
User constants for multi-function contact inputs are shown in the following tables.
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
H1-01
Terminal S3
function selec-
tion
Multi-function contact input
1
0 to 79 24 No A A A A A 400H -
端子 S3 功能设
定
H1-02
Terminal S4
function selec-
tion
Multi-function contact input
2
0 to 79 14 No A A A A A 401H -
端子 S4 设定
H1-03
Terminal S5
function selec-
tion
Multi-function contact input
3
0 to 79
3 (0)
*
No A A A A A 402H -
端子 S5 设定
H1-04
Terminal S6
function selec-
tion
Multi-function contact input
4
0 to 79
4 (3)
*
No A A A A A 403H -
端子 S6 设定
H1-05
Terminal S7
function selec-
tion
Multi-function contact input
5
0 to 79
6 (4)
*
No A A A A A 404H -
端子 S7 设定
H1-06
Terminal S8
function selec-
tion
Multi-function contact input
6
0 to 79
8 (6)
*
No A A A A A 405H -
端子 S8 设定
H1-07
Terminal S9
function selec-
tion
Multi-function contact input
7
0 to 79 5 No A A A A A 406H -
端子 S9 设定
H1-08
Terminal S10
function selec-
tion
Multi-function contact input
8
0 to 79 32 No A A A A A 407H -
端子 S10 设定
H1-09
Terminal S11
function selec-
tion
Multi-function contact input
9
0 to 79 7 No A A A A A 408H -
端子 S11 设定