Loading...
User Constant Tables
5-39
F1-05
PG rotation 0: Phase A leads with
Forward Run Command.
(Phase B leads with
Reverse Run Command.)
1: Phase B leads with
Forward Run Command.
(Phase A leads with
Reverse Run Command.)
0 or 1 0 No No A No A No 384H
6-158
PG 方向设定
F1-06
PG division
rate (PG
pulse moni-
tor)
Sets the division ratio for the
PG speed control board pulse
output.
Division ratio = (1+ n) /m
(n=0 or 1 m=1 to 32)
This constant is only effective
when a PG-B2 is used.
The possible division ratio
settings are: 1/32 F1-06 1.
1 to
132
1NoNoANoANo385H
6-159
PG 输出分频比
F1-07
Integral value
during accel/
decel enable/
disable
Sets integral control during
acceleration/deceleration to
either enabled or disabled.
0: Disabled (The integral
function isn't used while
accelerating or
decelerating; it is used at
constant speeds.)
1: Enabled (The integral
function is used at all
times.)
0 or 1 0 No No A No No No 386H
6-159
积分动作选择
F1-08
Overspeed
detection
level
Sets the overspeed detection
method.
Frequencies above that set for
F1-08 (set as a percentage of
the maximum output fre-
quency) that continue to
exceed this frequency for the
time set in F1-09 are detected
as overspeed faults.
0 to
120
115% No No A No A A 387H
6-159
过速检出值
F1-09
Overspeed
detection
delay time
0.0 to
2.0
0.0 s
*
No No A No A A 388H
6-159
OS 过速检出
时间
F1-10
Excessive
speed devia-
tion detec-
tion level
Sets the speed deviation
detection method.
Any speed deviation above
the F1-10 set level (set as a
percentage of the maximum
output frequency) that contin-
ues for the time set in F1-11 is
detected as a speed deviation.
Speed deviation is the differ-
ence between actual motor
speed and the reference com-
mand speed.
0 to 50 10% No No A No A A 389H
6-159
DEV 检出值
l
F1-11
Excessive
speed devia-
tion detec-
tion delay
time
0.0 to
10.0
0.5 s No No A No A A 38AH
6-159
DEV 检出时间
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
F1-06
nm

Table of Contents

Related product manuals