5-42
Analog Monitor Boards: F4
User constants for the Analog Monitor Board are shown in the following table.
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Regis-
ter
Page
Display
V/f
V/f
with
PG
Open
Loop
Vec-
tor
1
Flux
Vec-
tor
Open
Loop
Vec-
tor
2
F4-01
Channel 1
monitor
selection
Effective when the Analog
Monitor Board is used.
Monitor selection:
Set the number of the monitor
item to be output. (U1-)
Gain:
Set the multiple of 10 V for
outputting monitor items.
4, 10 to 14, 25, 28, 34, 39, 40
cannot be set. 29 to 31 and 41
are not used. When the AO-
12 Analog Monitor Board is
used, outputs of ± 10 V are
possible. To output ± 10 V, set
F4-07 or F4-08 to 1. When
the AO-08 Analog Monitor
Board is used, only outputs of
0 to +10 V are possible.
A meter calibration function
is available.
1 to 50 2 No A A A A A 391H 6-89
CH1 输出监视
F4-02
Channel 1
gain
0.00 to
2.50
1.00 Yes A A A A A 392H 6-89
CH1 输出增益
F4-03
Channel 2
monitor
selection
1 to 50 3 No A A A A A 393H 6-89
CH2 输出监视
F4-04
Channel 2
gain
0.00 to
2.50
0.50 Yes A A A A A 394H 6-89
CH2 输出增益
F4-05
Channel 1
output moni-
tor bias
Sets the channel 1 item bias
to 100%/10 V when the Ana-
log Monitor Board is used.
-10.0 to
10.0
0.0 Yes A A A A A 395H 6-89
AO CH1 偏置
F4-06
Channel 2
output moni-
tor bias
Sets the channel 2 item bias
to 100%/10 V when the Ana-
log Monitor Board is used.
-10.0 to
10.0
0.0 Yes A A A A A 396H 6-89
AO CH2 偏置
F4-07
Analog out-
put signal
level for
channel 1
0: 0 to 10 V
1: -10 to +10 V
0 or 1 0 No A A A A A 397H 6-89
CH1 信号电平
F4-08
Analog out-
put signal
level for
channel 2
0: 0 to 10 V
1: -10 to +10 V
0 or 1 0 No A A A A A 398H 6-89
CH2 信号电平