EasyManua.ls Logo

YASKAWA Z1000 - D: References

YASKAWA Z1000
466 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 7.41 Remove the Cooling Fan Unit: 2A0143 to 2A0273, 4A0156 to 4A0240
4.
Remove the fan guards and replace the cooling fans.
A
B
A Fan guards B Cooling fans
Figure 7.42 Cooling Fan Disassembly: 2A0143 to 2A0273, 4A0156 to 4A0240
n
Installing the Cooling Fan Unit: 2A0143 to 2A0273, 4A0156 to 4A0240
1.
Reverse the procedure to reinstall the cooling fan unit.
Note: Do not pinch the fan cable between parts when reassembling the fan unit.
Figure 7.43 Insert the Cooling Fan Unit: 2A0143 to 2A0273, 4A0156 to 4A0240
2.
Reattach the covers.
3.
Turn on the power supply and set o4-03 to 0 to reset the Maintenance Monitor cooling fan operation time.
7.5 Drive Cooling Fans
YASKAWA ELECTRIC SIEP YAIZ1B 01E YASKAWA AC Drive – Z1000 Bypass Technical Manual
293
7
Periodic Inspection &
Maintenance

Table of Contents

Other manuals for YASKAWA Z1000