EasyManua.ls Logo

YASKAWA Z1000 - Page 326

YASKAWA Z1000
466 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No.
(Addr.
Hex)
Name Description Values Page
H3-14
(41C)
Analog Input Terminal
Enable Selection
A1/A2 Sel
Determines which analog input terminals will be enabled when a digital input
programmed for “Analog input enable” (H1-oo = C) is activated.
1: Terminal A1 only
1: A1 Available
2: Terminal A2 only
2: A2 Available
3: Terminals A1 and A2
3: A1/A2 Available
Default: 2
Range: 1 to 3
162
H3-16
(2F0)
Terminal A1 Offset
Term A1 Offset
Adds an offset when the analog signal to terminal A1 is at 0 V. Default: 0
Min.: -500
Max.: 500
163
H3-17
(2F1)
Terminal A2 Offset
Term A2 Offset
Adds an offset when the analog signal to terminal A2 is at 0 V. Default: 0
Min.: -500
Max.: 500
163
H3 Multi-Function Analog Input Settings
H3-oo
Setting
Function Description Page
0
Frequency bias
Freq Ref Bias
10 V = E1-04 (maximum output frequency)
163
1
Frequency gain
Freq Ref Gain
0 to 10 V signal allows a setting of 0 to 100%. -10 to 0 V signal allows a setting of -100
to 0%.
163
2
Auxiliary frequency reference 1
(used as a Multi-Step Speed 2)
Aux Reference1
10 V = E1-04 (maximum output frequency)
163
3
Auxiliary frequency reference 2
(3rd step analog)
Aux Reference2
10 V = E1-04 (maximum output frequency)
164
4
Output voltage bias
Voltage Bias
10 V = E1-05 (motor rated voltage)
164
5
Accel/decel time gain
Acc/Dec Time Gain
10 V = 100%
164
6
DC Injection Braking current
DC Brake Current
10 V = Drive rated current
164
7
Overtorque/undertorque
detection level
Torque Det Level
10 V = Drive rated current (V/f)
164
8
Stall Prevention level during run
Stall Prev Level
10 V = Drive rated current
164
9
Output frequency lower limit level
Ref Lower Limit
10 V = E1-04 (maximum output frequency)
165
B
PI feedback
PI Feedback1
10 V = 100%
165
C
PI setpoint
PI Set Point
10 V = 100%
165
D
Frequency bias
Freq Ref Bias 2
10 V = E1-04 (maximum output frequency)
165
E
Motor temperature (PTC input)
Motor PTC
10 V = 100%
165
F
Through mode
Not Used
Set this value when using the terminal in the pass-through mode.
165
16
Differential PI feedback
PI Feedback 2
10 V = 100%
165
1F
<1>
HAND Reference
Hand Ref
Sets the frequency reference when in HAND Mode and parameter Z1-41, HAND Speed
Reference Selection, is set to 1 (Analog).
165
25
Secondary PI setpoint
PI2 Setpoint
10 V = S3-02 (maximum output frequency) 165
26
Secondary PI feedback
PI2 Feedback
10 V = S3-02 (maximum output frequency) 165
<1> Setting 1F is “HAND Reference” in bypass controller software versions VST800298 and later. Setting 1F is “Not Used (Through Mode)” in bypass
controller software versions VST800297 and earlier.
B.8 H Parameters: Multi-Function Terminals
326
YASKAWA ELECTRIC SIEP YAIZ1B 01E YASKAWA AC Drive – Z1000 Bypass Technical Manual