No.
(Addr.
Hex)
Name Description
Analog Output
Level
Unit
U3-28
(3012)
Date Month and Day at 3rd
Most Recent Fault
Fault 3 MMDD
Displays the date and day when the third most recent fault occurred.
No signal output
available
U3-29
(3013)
Time Hours and Minutes
at 3rd Most Recent Fault
Fault 3 HHMM
Displays the time when the third most recent fault occurred.
No signal output
available
U3-30
(3014)
Date Year at 4th Most
Recent Fault
Fault 4 YYYY
Displays the year when the fourth most recent fault occurred.
No signal output
available
U3-31
(3015)
Date Month and Day at 4th
Most Recent Fault
Fault 4 MMDD
Displays the date and day when the fourth most recent fault occurred.
No signal output
available
U3-32
(3016
Time Hours and Minutes
at 4th Most Recent Fault
Fault 4 HHMM
Displays the time when the fourth most recent fault occurred.
No signal output
available
U3-33
(3017)
Date Year at 5th Most
Recent Fault
Fault 5 YYYY
Displays the year when the fifth most recent fault occurred.
No signal output
available
U3-34
(3018)
Date Month and Day at 5th
Most Recent Fault
Fault 5 MMDD
Displays the date and day when the fifth most recent fault occurred.
No signal output
available
U3-35
(3019)
Time Hours and Minutes
at 5th Most Recent Fault
Fault 5 HHMM
Displays the time when the fifth most recent fault occurred.
No signal output
available
U3-36
(301A)
Date Year at 6th Most
Recent Fault
Fault 6 YYYY
Displays the year when the sixth most recent fault occurred.
No signal output
available
U3-37
(301B)
Date Month and Day a 6th
Most Recent Fault
Fault 6 MMDD
Displays the date and day when the sixth most recent fault occurred.
No signal output
available
U3-38
(301C)
Time Hours and Minutes
at 6th Most Recent Fault
Fault 6 HHMM
Displays the time when the most sixth recent fault occurred.
No signal output
available
U3-39
(301D)
Date Year at 7th Most
Recent Fault
Fault 7 YYYY
Displays the year when the most seventh recent fault occurred.
No signal output
available
U3-40
(301E)
Date Month and Day at 7th
Most Recent Fault
Fault 7 MMDD
Displays the date and day when the seventh most recent fault occurred.
No signal output
available
U3-41
(301F)
Time Hours and Minutes
at 7th Most Recent Fault
Fault 7 HHMM
Displays the time when the seventh most recent fault occurred.
No signal output
available
U3-42
(3020)
Date Year at 8th Most
Recent Fault
Fault 8 YYYY
Displays the year when the eighth most recent fault occurred.
No signal output
available
U3-43
(3021)
Date Month and Day 8th at
Most Recent Fault
Fault 8 MMDD
Displays the date and day when the eighth most recent fault occurred.
No signal output
available
U3-44
(3022)
Time Hours and Minutes
at 8th Most Recent Fault
Fault 8 HHMM
Displays the time when the eighth most recent fault occurred.
No signal output
available
U3-45
(3023)
Date Year at 9th Most
Recent Fault
Fault 9 YYYY
Displays the year when the ninth most recent fault occurred.
No signal output
available
U3-46
(3024)
Date Month and Day at 9th
Most Recent Fault
Fault 9 MMDD
Displays the date and day when the ninth most recent fault occurred.
No signal output
available
U3-47
(3025)
Time Hours and Minutes
at 9th Most Recent Fault
Fault 9 HHMM
Displays the time when the ninth most recent fault occurred.
No signal output
available