EasyManua.ls Logo

YASKAWA Z1000 - Page 96

YASKAWA Z1000
466 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AUTO LED HAND LED State
AUTO
Off
HAND
Double blink
HAND mode, cycle the Run command.
AUTO
Long blink (50% duty)
HAND
Off
Running in AUTO mode when the Frequency Reference is 0 and/or decelerating in AUTO
mode, or during PI Sleep or Snooze.
AUTO
Short blink (15% duty)
HAND
Off
AUTO mode, Ready, No run command input.
AUTO
Double blink
HAND
Off
AUTO mode, stopped by a Fast- Stop from a Multi-Function Digital Input.
Long blink
(50% duty)
Double blink
Short link
(15% duty)
1 s
2 s
ON ON ON
ON ON ON ON ON ON
ON ON
Figure 4.4 AUTO LED and HAND LED Timing Status
OFF ON Blink OFF Blink OFF
Output Frequency
RUN Command
Frequency
AUTO LED
HAND Mode Selection
AUTO Mode Selection
OFF AUTOOperation Mode
OFFHAND LED
OFF
0 Hz
6 Hz
ON
Short blink
Figure 4.5 LEDs and Drive Operation in AUTO and HAND Modes
4.2 Using the HOA Keypad
96
YASKAWA ELECTRIC SIEP YAIZ1B 01E YASKAWA AC Drive – Z1000 Bypass Technical Manual

Table of Contents

Other manuals for YASKAWA Z1000

Related product manuals