5-18
IM DLM4038-17EN
Command Function Page
:MEASure:{CHANnel<x>|MATH<x>}{[
:AREA1]|:AREA2}:<Parameter>:VAL
ue?
Queries an automatically measured value of a waveform parameter in the
specified area.
5-139
:MEASure:{CHANnel<x>|MATH<x>}
{[:AREA1]|:AREA2}:COPY
Copies the on/off status of all measurement items of a waveform to all other
waveforms in the specified area.
5-140
:MEASure:{CHANnel<x>|MATH<x>}
{[:AREA1]|:AREA2}:CYCLe
Sets or queries a cycle mode in the specified area. 5-140
:MEASure:{CHANnel<x>|MATH<x>}
{[:AREA1]|:AREA2}:DELay?
Queries all of the settings for measuring the delay between channels of a
waveform in the specified area.
5-140
:MEASure:{CHANnel<x>|MATH<x>}
{[:AREA1]|:AREA2}:DELay:MEASu
re?
Queries all of the settings for a source waveform for measuring the delay
between channels of a waveform in the specified area.
5-140
:MEASure:{CHANnel<x>|MATH<x>}
{[:AREA1]|:AREA2}:DELay:MEASure
:COUNt
Sets or queries the count number of a source waveform for measuring the
delay between channels of a waveform in the specified area.
5-140
:MEASure:{CHANnel<x>|MATH<x>}
{[:AREA1]|:AREA2}:DELay:MEASure
:SLOPe
Sets or queries the slope of a source waveform for measuring the delay
between channels of a waveform in the specified area.
5-140
:MEASure:{CHANnel<x>|MATH<x>}
{[:AREA1]|:AREA2}:DELay:REFeren
ce?
Queries all reference waveform settings used to measure the delay between
the specified waveform and the reference waveform in the specified area.
5-140
:MEASure:{CHANnel<x>|MATH<x>}
{[:AREA1]|:AREA2}:DELay:REFeren
ce:COUNt
Sets or queries the edge count of the reference waveform used to measure
the delay between the specified waveform and the reference waveform in the
specified area.
5-141
:MEASure:{CHANnel<x>|MATH<x>}
{[:AREA1]|:AREA2}:DELay:REFeren
ce:SLOPe
Sets or queries the slope of the reference waveform used to measure the
delay between the specified waveform and the reference waveform in the
specified area.
5-141
:MEASure:{CHANnel<x>|MATH<x>}
{[:AREA1]|:AREA2}:DELay:REFeren
ce:SOURce
Sets or queries whether the reference point for measuring the delay between
channels of a waveform will be set to the trigger point or a waveform in the
specified area.
5-141
:MEASure:{CHANnel<x>|MATH<x>}
{[:AREA1]|:AREA2}:DELay:REFeren
ce:TRACe
Sets or queries the reference waveform edge used to measure the delay
between the specified waveform and the reference waveform in the specified
area.
5-141
:MEASure:{CHANnel<x>|MATH<x>}:D
PRoximal?
Queries all distal, mesial, and proximal settings. 5-141
:MEASure:{CHANnel<x>|MATH<x>}:D
PRoximal:MODE
Sets or queries the distal, mesial, and proximal point mode setting. 5-142
:MEASure:{CHANnel<x>|MATH<x>}:D
PRoximal:PERCent
Sets or queries the distal, mesial, and proximal points as percentages. 5-142
:MEASure:{CHANnel<x>|MATH<x>}:D
PRoximal:UNIT
Sets or queries the distal, mesial, and proximal points as voltages. 5-142
:MEASure:{CHANnel<x>|MATH<x>}:M
ETHod
Sets or queries the high/low point setting method. 5-142
:MEASure:CONTinuous?
Queries all settings for the normal statistical processing of automatically
measured waveform parameters.
5-142
:MEASure:CONTinuous:RESTart
Restarts the normal statistical processing of automatically measured
waveform parameters.
5-142
:MEASure:CONTinuous:TLCHange
(Trigger Level Change)
Sets or queries whether normal statistical processing of automatically
measured waveform parameters is restarted when the trigger level is
changed.
5-142
:MEASure:CYCLe?
Queries all cyclic statistical processing settings for automated measurement. 5-142
:MEASure:CYCLe:ABORt
Aborts cyclic statistical processing for automated measurement. 5-142
:MEASure:CYCLe:EXECute
Executes cyclic statistical processing for automated measurement. 5-142
:MEASure:CYCLe:TRACe
Sets or queries the source waveform used in the cyclic statistical processing
for automated measurement.
5-143
:MEASure:HISTory:ABORt
Aborts statistical processing of automatically measured history waveforms. 5-143
:MEASure:HISTory:EXECute
Executes statistical processing of automatically measured history waveforms. 5-143
:MEASure:INDicator
Sets or queries the measurement location indicator. 5-143
:MEASure:MODE
Sets or queries the on/off/statistical processing status of automated
measurement.
5-143
:MEASure:{PODA<x>|PODB<x>|PODL
<x>}?
Queries all the parameter on/off status of the logic waveform. 5-143
:MEASure:{PODA<x>|PODB<x>|PODL
<x>}{[:AREA1]|:AREA2}?
Queries all the parameter on/off status of the logic waveform in the specified
area.
5-143
5.1 List of Commands