5-33
IM DLM4038-17EN
Commands
5
Command Function Page
:SERialbus<x>:PSI5:SEARch[:SETu
p]:ERRor:PCRC
Sets or queries the PSI5 signal parity/CRC error search. 5-204
:SERialbus<x>:PSI5:SEARch[:SETu
p]:ERRor:SBIT
Sets or queries the PSI5 signal start bit error search. 5-204
:SERialbus<x>:PSI5:SEARch[:SETu
p]:ERRor:SBOundary
Sets or queries the PSI5 signal slot boundary error search. 5-205
:SERialbus<x>:PSI5:SEARch[:SETu
p]:FRAMeinslot?
Queries all PSI5 signal slot specification search settings. 5-205
:SERialbus<x>:PSI5:SEARch[:SETu
p]:FRAMeinslot:SNUMber
Sets or queries the slot number of the PSI5 signal slot specification search. 5-205
:SERialbus<x>:PSI5:SEARch[:SETu
p]:MODE
Sets or queries the PSI5 signal search mode setting. 5-205
:SERialbus<x>:PSI5:TRENd<y>?
Queries all PSI5 signal analysis trend display settings. 5-205
:SERialbus<x>:PSI5:TRENd<y>:ASC
ale
Executes auto scaling of the PSI5 signal analysis trend display. 5-205
:SERialbus<x>:PSI5:TRENd<y>:CUR
Sor?
Queries all PSI5 signal analysis trend display cursor measurement settings. 5-205
:SERialbus<x>:PSI5:TRENd<y>:CUR
Sor:DT:VALue?
Queries the time value between cursors on the PSI5 signal analysis trend
display.
5-205
:SERialbus<x>:PSI5:TRENd<y>:CUR
Sor:DV:VALue?
Queries the vertical value between cursors on the PSI5 signal analysis trend
display.
5-205
:SERialbus<x>:PSI5:TRENd<y>:CUR
Sor:MODE
Sets or queries the cursor mode on the PSI5 signal analysis trend display. 5-205
:SERialbus<x>:PSI5:TRENd<y>:CUR
Sor:POSition<z>
Sets or queries the position of the specified cursor on the PSI5 signal
analysis trend display.
5-206
:SERialbus<x>:PSI5:TRENd<y>:CUR
Sor:T<z>:VALue?
Queries the time value at the specified cursor on the PSI5 signal analysis
trend display.
5-206
:SERialbus<x>:PSI5:TRENd<y>:CUR
Sor:V<z>:VALue?
Queries the vertical value at the specified cursor on the PSI5 signal analysis
trend display.
5-206
:SERialbus<x>:PSI5:TRENd<y>:DIS
Play
Sets or queries the on/off status of the PSI5 signal analysis trend display. 5-206
:SERialbus<x>:PSI5:TRENd<y>:HRA
Nge
Sets or queries the PSI5 signal analysis trend display source window. 5-206
:SERialbus<x>:PSI5:TRENd<y>:SOU
Rce
Sets or queries the target slot number of the PSI5 signal analysis trend
display.
5-206
:SERialbus<x>:PSI5:TRENd<y>:VER
Tical
Sets or queries the vertical range of the PSI5 signal analysis trend display. 5-206
:SERialbus<x>:PSI5:TRENd<y>:VTD
isplay
Sets or queries the on/off status of the VT waveform display on the PSI5
signal analysis trend display.
5-206
:SERialbus<x>:RWINdow
Sets or queries in which zoom window, ZOOM1 or ZOOM2, the detected
section will be displayed.
5-207
:SERialbus<x>:SENT?
Queries all SENT signal analysis and search settings. 5-207
:SERialbus<x>:SENT:ANALyze?
Queries all SENT signal analysis settings. 5-207
:SERialbus<x>:SENT[:ANALyze]:SE
Tup?
Queries all bus setup settings for SENT signal analysis. 5-207
:SERialbus<x>:SENT[:ANALyze]:SE
Tup:DISPlay
Sets or queries the display mode for the SENT signal analysis result. 5-207
:SERialbus<x>:SENT[:ANALyze]:SE
Tup:FAST?
Queries all SENT signal analysis fast channel settings. 5-207
:SERialbus<x>:SENT[:ANALyze]:SE
Tup:FAST:DTYPe
Sets or queries the SENT signal analysis fast channel data format. 5-207
:SERialbus<x>:SENT[:ANALyze]:SE
Tup:FAST:USETup?
Queries all settings related to fast channel user-defined data of SENT signal
analysis.
5-207
:SERialbus<x>:SENT[:ANALyze]:SE
Tup:FAST:USETup:DATA<y>?
Queries all settings related to the specified user-defined data of the SENT
signal analysis fast channel.
5-207
:SERialbus<x>:SENT[:ANALyze]:SE
Tup:FAST:USETup:DATA<y>:MODE
Sets or queries the enable/disable condition of the specified user-defined
data of the SENT signal analysis fast channel.
5-207
:SERialbus<x>:SENT[:ANALyze]:SE
Tup:FAST:USETup:DATA<y>:ORDer
Sets or queries the byte order of the specified user-defined data of the SENT
signal analysis fast channel.
5-208
:SERialbus<x>:SENT[:ANALyze]:SE
Tup:FAST:USETup:DATA<y>:SIZE
Sets or queries the data size of the specified user-defined data of the SENT
signal analysis fast channel.
5-208
:SERialbus<x>:SENT[:ANALyze]:SE
Tup:FAST:USETup:MULTiplexing
Sets or queries the enable/disable condition of the multiplexing for the user-
defined data of the the SENT signal analysis fast channel.
5-208
5.1 List of Commands