User’s Manual 1PH HYD3000-HYD6000-ZSS
Rev. 1.1 16/03/2021
Identification: MD-AL-GI-00
Rev. 1.1 of 16/03/2021 - Application: GID
Battery
overvoltage protection
Battery
undervoltage protection
Battery
overtemperature
protection while
discharging
Make sure that the battery is in a well-
ventilated place.
Try to decrease the maximum discharge (A)
and/or maximum charge (A) to see if the
problem is fixed.
Battery
overtemperature
protection while
charging
Battery low temperature
protection while
discharging
Try to increase the ambient temperature in
the battery location.
Battery low temperature
protection while
discharging
9.1. Maintenance
Inverters generally do not require daily or routine maintenance. In any case, for proper long-term operation
of the inverter, make sure that the heatsink for cooling the inverter has enough space to ensure adequate
ventilation and that it is not obstructed by dust or other items.
Cleaning the inverter
Use an air compressor, a soft dry cloth or a soft-bristled brush to clean the inverter. Do not use water,
corrosive chemicals or aggressive detergents to clean the inverter. Disconnect the AC and DC power to the
inverter before performing any cleaning operations.
Cleaning the heatsink
Use an air compressor, a soft dry cloth or soft-bristled brush to clean the heatsink. Do not use water,
corrosive chemical substances or aggressive detergents to clean the heatsink. Disconnect the AC and DC
power to the inverter before performing any cleaning operations.