Length 1 - Use to set decode lengths (default - 4). See Decode Lengths for more information.
Length 2 - Use to set decode lengths (default - 55). See Decode Lengths for more information.
Redundancy - Sets the reader to read the barcode twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - enabled).
Report Check Digit - Transmit MSI data with or without the check digit. A check in the checkbox indicates
to send MSI data with check digit (default - disabled).
Trioptic 39
Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - disabled).
UK Postal
Report Check Digit - Transmit UK Postal data with or without the check digit. A check in the checkbox
indicates to send UK Postal data with check digit (default - disabled).
UPCA
Preamble - Preamble characters are part of the UPC symbol consisting of Country Code and System
Character. Select the appropriate option to match the host system.
There are three options for transmitting a UPCA preamble:
Preamble None - Transmit no preamble.
Preamble Sys Char - Transmit System Character only (default).
Preamble Country and Sys Char - Transmit System Character and Country Code (“0for USA). Select
the appropriate option to match the host system.
Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of the
data. Enables or disables this option. A check in the checkbox indicates that the option is enabled (default -
enabled).
UPCE0
Convert UPCE0 To UPCA - Enable to convert UPCE0 (zero suppressed) decoded data to UPC-A format
before transmission. After conversion, the data follows UPC-A format and is affected by UPC-A
programming selections. Disable to transmit UPCE0 decoded data as UPCE0 data, without conversion
(default - disabled).
Preamble - Preamble characters are part of the UPC symbol consisting of Country Code and System
Character. Select the appropriate option to match the host system.
There are three options for transmitting a UPCE0 preamble:
Preamble None - Transmit no preamble (default).
Preamble Sys Char - Transmit System Character only.
Preamble Country and Sys Char
- Transmit System Character and Country Code (“0” for USA).
Report Check Digit - The check digit is the last character of the symbol used to verify the integrity of the
data. Enables or disables this option. A check in the checkbox indicates that the option is enabled (default -
disabled).
UPCE1
Convert UPCE1 To UPCA - Enable this to convert UPCE1 decoded data to UPC-A format before
transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming
selections. Disable this to transmit UPCE1 decoded data as UPCE1 data, without conversion (default -
disabled).

Table of Contents

Other manuals for Zebra MC93 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra MC93 Series and is the answer not in the manual?

Zebra MC93 Series Specifications

General IconGeneral
BrandZebra
ModelMC93 Series
CategoryPDA
LanguageEnglish

Related product manuals