Page #144 background image
DataWedge
144
Switch To Profile
Use the SwitchToProfile API action to switch to the specified Profile.
Profiles Recap
DataWedge is based on Profiles and plug-ins. A Profile contains information on how DataWedge should
behave with different applications.
Profile information consists of:
Associated application
Input plug-in configurations
Output plug-in configurations
Process plug-in configurations
DataWedge includes a default Profile, Profile0, that is created automatically the first time DataWedge runs.
Using Profiles, each application can have a specific DataWedge configuration. For example, each user
application can have a Profile which outputs scanned data in the required format when that application comes
to the foreground. DataWedge can be configured to process the same set of captured data differently based on
the requirements of each application.
NOTE: Use of this API changes only the runtime status of the scanner; it does not make persistent changes to the Profile.
A single Profile may be associated with one or many activities/apps, however, given an activity, only one Profile may be
associated with it.
Usage Scenario
An application has two activities. Activity A only requires EAN13 bar codes to be scanned. Activity B only
requires Code 128 bar codes to be scanned. Profile EAN13 is configured to only scan EAN13 bar codes and is
left unassociated. Profile Code128 is configured to scan Code 128 and is left unassociated. When Activity A
launches it uses SwitchToProfile to activate Profile EAN13. Similarly, when Activity B launches it uses
switchToProfile to activate Profile Code128.
If another activity/app comes to the foreground, DataWedge auto Profile switching will set the DataWedge
Profile accordingly either to the default Profile or to an associated Profile.
When Activity A (or Activity B) comes back to the foreground it will use switchToProfile to reset the Profile back
to Profile B (or Profile M).
Function Prototype
Parameters
ACTION [String]: "com.symbol.datawedge.api.ACTION"
EXTRA_DATA [String]: "com.symbol.datawedge.api.SWITCH_TO_PROFILE"
Intent i = new Intent();
i.setAction("com.symbol.datawedge.api.ACTION");
i.putExtra("com.symbol.datawedge.api.SWITCH_TO_PROFILE", "<profile name>");

Table of Contents

Other manuals for Zebra MC93 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra MC93 Series and is the answer not in the manual?

Zebra MC93 Series Specifications

General IconGeneral
Operating Temperature-4°F to 122°F/-20°C to 50°C
ProcessorQualcomm Snapdragon 660 octa-core, 2.2 GHz
Operating SystemAndroid 11
RAM4 GB
Storage32 GB Flash
Battery7000 mAh
ConnectivityUSB 2.0
Camera13 MP rear camera
Drop SpecificationMultiple 8 ft. / 2.4 m drops to concrete per MIL-STD 810G across operating temperature range
SealingIP65
Touch PanelCapacitive Corning Gorilla Glass
Keypad OptionsNumeric, Function Numeric, Alpha-Numeric
Scanning1D/2D
Wireless LAN802.11 a/b/g/n/ac
AudioSpeaker, microphone
Display4.3 in. WVGA (800 x 480), color TFT-LCD with backlight

Related product manuals