Extracting Log Files
1. Connect the device to a host computer using an USB connection.
2. Using a file explorer, navigate to the
RxLogger folder.
3. Copy the file from the device to the host computer.
4. Disconnect the device from the host computer.
RxLogger Utility
RxLogger Utility is a data monitoring application for viewing logs in the device while RxLogger is running. Logs
and RxLogger Utility features are accessed in the App View or the Overlay View.
App View
In App View, the user views logs in the RxLogger Utility.
Figure 78 App View
Viewing Logs
To view logs:
1. Touch the Main Chat Head icon. The Overlay View screen appears.

Table of Contents

Other manuals for Zebra MC93 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra MC93 Series and is the answer not in the manual?

Zebra MC93 Series Specifications

General IconGeneral
Operating Temperature-4°F to 122°F/-20°C to 50°C
ProcessorQualcomm Snapdragon 660 octa-core, 2.2 GHz
Operating SystemAndroid 11
RAM4 GB
Storage32 GB Flash
Battery7000 mAh
ConnectivityUSB 2.0
Camera13 MP rear camera
Drop SpecificationMultiple 8 ft. / 2.4 m drops to concrete per MIL-STD 810G across operating temperature range
SealingIP65
Touch PanelCapacitive Corning Gorilla Glass
Keypad OptionsNumeric, Function Numeric, Alpha-Numeric
Scanning1D/2D
Wireless LAN802.11 a/b/g/n/ac
AudioSpeaker, microphone
Display4.3 in. WVGA (800 x 480), color TFT-LCD with backlight