P1075391-001 • ZQ520 Repair Procedures • 2-28 •
5. Attach the Reverse Tear Bar onto
the Platen Holder with the three
(3) screws at a T-8 driver (2.5 +/- 1
in. lb.).
6. Insert the Platen Cartridge
Assembly into the media cover
frame in the orientation shown.
7. Use a TORX T-8 driver (4.7 +/-
1 in. lb.) to secure the Platen
Cartridge Assembly to the media
cover frame with the four (4)
screws.