EasyManua.ls Logo

ZyXEL Communications GS1350 Series - Page 201

ZyXEL Communications GS1350 Series
417 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 25 Error Disable
GS1350 Series User’s Guide
201
Figure 147 Advanced Application > Errdisable > Errdisable Status
The following table describes the labels in this screen.
Table 89 Advanced Application > Errdisable > Errdisable Status
LABEL DESCRIPTION
Inactive-reason
mode reset
Port List Enter the number of the ports (separated by a comma) on which you want to reset inactive-
reason status.
Cause Select the cause of inactive-reason mode you want to reset here.
Reset Press to reset the specified ports to handle ARP, BPDU or IGMP packets instead of ignoring them,
if the ports is in inactive-reason mode.
Errdisable Status
Port This is the number of the port on which you want to configure Errdisable Status.
Cause This displays the type of the control packet received on the port or the feature enabled on the
port and causing the Switch to take the specified action.
Active This field displays whether the control packets (ARP, BPDU, and/or IGMP) on the port is being
detected or not. It also shows whether loop guard, anti-arp scanning, BPDU guard or ZULD is
enabled on the port.