EasyManua.ls Logo

ZyXEL Communications GS1350 Series - Page 282

ZyXEL Communications GS1350 Series
417 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 34 Access Control
GS1350 Series User’s Guide
282
Table 141 SNMP Interface Traps
OPTION OBJECT LABEL OBJECT ID DESCRIPTION
linkup linkUp 1.3.6.1.6.3.1.1.5.4 This trap is sent when the Ethernet link
is up.
linkdown linkDown 1.3.6.1.6.3.1.1.5.3 This trap is sent when the Ethernet link
is down.
lldp lldpRemTablesChange 1.0.8802.1.1.2.0.0.1 The trap is sent when entries in the
remote database have any updates.
Link Layer Discovery Protocol (LLDP),
defined as IEEE 802.1ab, enables LAN
devices that support LLDP to
exchange their configured settings.
This helps eliminate configuration
mismatch issues.
transceiver-ddm zyTransceiverDdmiTemperature
OutOfRange
1.3.6.1.4.1.890.1.15.3.84.3.1 This trap is sent when the transceiver
temperature is above or below the
normal operating range.
zyTransceiverDdmiTxPowerOutO
fRange
1.3.6.1.4.1.890.1.15.3.84.3.2 This trap is sent when the transmitted
optical power is above or below the
normal operating range.
zyTransceiverDdmiRxPowerOutO
fRange
1.3.6.1.4.1.890.1.15.3.84.3.3 This trap is sent when the received
optical power is above or below the
normal operating range.
zyTransceiverDdmiVoltageOutO
fRange
1.3.6.1.4.1.890.1.15.3.84.3.4 This trap is sent when the transceiver
supply voltage is above or below the
normal operating range.
zyTransceiverDdmiTxBiasOutOfR
ange
1.3.6.1.4.1.890.1.15.3.84.3.5 This trap is sent when the transmitter
laser bias current is above or below
the normal operating range.
zyTransceiverDdmiTemperature
OutOfRangeRecovered
1.3.6.1.4.1.890.1.15.3.84.3.6 This trap is sent when the transceiver
temperature is recovered from the
out of normal operating range.
zyTransceiverDdmiTxPowerOutO
fRangeRecovered
1.3.6.1.4.1.890.1.15.3.84.3.7 This trap is sent when the transmitted
optical power is recovered from the
out of normal operating range.
zyTransceiverDdmiRxPowerOutO
fRangeRecovered
1.3.6.1.4.1.890.1.15.3.84.3.8 This trap is sent when the received
optical power is recovered from the
out of normal operating range.
zyTransceiverDdmiVoltageOutO
fRangeRecovered
1.3.6.1.4.1.890.1.15.3.84.3.9 This trap is sent when the transceiver
supply voltage is recovered from the
out of normal operating range.
zyTransceiverDdmiTxBiasOutOfR
angeRecovered
1.3.6.1.4.1.890.1.15.3.84.3.10 This trap is sent when the transmitter
laser bias current is recovered from
the out of normal operating range.
Storm-control zyPortStormControlTrap 1.3.6.1.4.1.890.1.15.3.78.2.1 This trap is sent when storm control is
detected on a specific port. A packet
filter action has been applied on the
interface.

Table of Contents