Chapter 8 Storage Manager
Cloud Storage User’s Guide
94
Advanced
Go to Advanced screen for other configurations such as CRC checksum and maximum receive/
send segments.
Figure 55 iSCSI Targets > Edit > Advanced
Table 27 iSCSI Targets > Edit > Map iSCSI LUNs
LABEL DESCRIPTION
Status Displays the status of the iSCSI LUN.
LUN Name Displays the iSCSI LUN name.
Capacity Displays the size of the iSCSI LUN.
Apply Select the check to choose a LUN, and click Apply to save your changes.
Cancel Click Cancel to close the screen without saving any settings.
Table 28 iSCSI Targets > Edit > Advanced
LABEL DESCRIPTION
CRC checksum Cyclic Redundancy Check (CRC) checksum is a technique for detecting data transmission
errors. It ensures correct data transmissions between the initiator and the target. If you
select the Data/Header Digest, the iSCSI initiator will be verified by these parameters
when transmitting data.
Data digest Select the check box to enable data digest. The data digest protects the integrity of the
data.
Header digest Select the check box to enable header digest. The header digest protects the integrity of
the header.
Maximum receive
segment bytes
Select the maximum receive segments allowed in bytes.
Four options are applied: 262144, 65536, 9182, 4092.