EasyManua.ls Logo

ABB A145-M65 - Commissioning; Oil Supply

ABB A145-M65
142 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual / 4 Product description / A130-M.. - A145-M..
3 Commissioning / 3.1 Oil supply
© Copyright 2017 ABB. All rights reserved. HZTL4031_EN Revision F August 2017
3 Commissioning
3.1 Oil supply
3.1.1 Introduction
In all operating states, a functioning and carefully executed oil supply is an important pre-
requisite for trouble-free operation of the turbocharger.
The lubrication of the turbocharger is usually carried out with oil from the engine oil circula-
tion.
u Comply with the enginebuilder's specifications regarding the selection of lubricating oil
and the oil change intervals.
3.1.2 Pre-lubrication
Pre-lubrication must be carried out as follows:
u Switch on the oil pump.
u Build up oil pressure (see Table6: Lubricating oil pressure, oil inlet 25).
u Do not exceed a pre-lubrication time of 2 minutes.
u Start the engine.
u Let the oil pump run until the pump driven by the engine generates sufficient pressure.
3.1.3 Oil filtering
Filtering the lubricating oil with a filter mesh width of ≤0.034mm is sufficient for this tur-
bocharger.
3.1.4 Oil pressure
Comply precisely with the oil pressure before the turbocharger for trouble-free operation.
The admissible values are specified in chapter Monitoring operation 25.
Page 20 / 111