EasyManua.ls Logo

ABB A145-M65 - Malfunctions When Stopping; Table 28: Malfunctions When Stopping - Runout Noises; Table 29: Malfunctions When Stopping - Runout Time too Short

ABB A145-M65
142 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Manual / 4 Product description / A130-M.. - A145-M..
7 Eliminating malfunctions / 7.4 Malfunctions when stopping
© Copyright 2017 ABB. All rights reserved. HZTL4031_EN Revision F August 2017
7.4 Malfunctions when stopping
Runout noises
Possible causes Remedy
Turbocharger Turbocharger contaminated Clean (see chapter Periodic maintenance work 40)
Bearing damaged Check clearances (see chapter Axial clearance A and
radial clearance B 84). If clearances are outside
the tolerance or if in doubt, contact an ABB Tur-
bocharging Service Station.
Rotor rubbing Check clearances (see chapter Radial clearances N
and R 92). If clearances are outside the tolerance
or if in doubt, contact an ABB Turbocharging Ser-
vice Station.
Foreign object in the tur-
bocharger
Dismantle turbocharger (see chapter Dismantling
and fitting 66). In case of damage, replace the
corresponding parts or contact an ABB Turbochar-
ging Service Station.
Table28: Malfunctions when stopping – Runout noises
Runout time too short
The runout time must be noted down as a reference. Because the runout time depends on
the oil viscosity, the runout time must always be measured at the same oil temperature.
If the runout time is significantly shorter in comparison to a previous measurement, the fol-
lowing table must be observed.
Possible causes Remedy
Turbocharger Turbocharger contaminated Clean (see chapter Periodic maintenance work 40)
Bearing damaged Check clearances (see chapter Axial clearance A and
radial clearance B 84). If clearances are outside
the tolerance or if in doubt, contact an ABB Tur-
bocharging Service Station.
Rotor rubbing Check clearances (see chapter Radial clearances N
and R 92). If clearances are outside the tolerance
or if in doubt, contact an ABB Turbocharging Ser-
vice Station.
Foreign object in the tur-
bocharger
Dismantle turbocharger (see chapter Dismantling
and fitting 66). In case of damage, replace the
corresponding parts or contact an ABB Turbochar-
ging Service Station.
Table29: Malfunctions when stopping – Runout time too short
Page 64 / 111

Table of Contents

Related product manuals