Additional parameter data 185
Parameter groups 10…99
No. Name Type Range Unit FbEq32
10 Standard DI, RO
10.02 DI delayed status PB 0b0000...0b1111 - 1 = 1
10.03 DI force selection PB 0b0000...0b1111 - 1 = 1
10.04 DI forced data PB 0b0000...0b1111 - 1 = 1
10.21 RO status PB 0b0000...0b1111 - 1 = 1
10.22 RO force selection PB 0b0000...0b1111 - 1 = 1
10.23 RO forced data PB 0b0000...0b1111 - 1 = 1
10.24 RO1 source Binary src --1 = 1
10.25 RO1 ON delay Real 0.0…3000.0 s 10 = 1 s
10.26 RO1 OFF delay Real 0.0…3000.0 s 10 = 1 s
10.27 RO2 source Binary src --1 = 1
10.28 RO2 ON delay Real 0.0…3000.0 s 10 = 1 s
10.29 RO2 OFF delay Real 0.0…3000.0 s 10 = 1 s
10.30 RO3 source Binary src --1 = 1
10.31 RO3 ON delay Real 0.0…3000.0 s 10 = 1 s
10.32 RO3 OFF delay Real 0.0…3000.0 s 10 = 1 s
10.99 RO/DIO control word PB 0b0000...0b1111 - 1 = 1
10.101 RO1 toggle counter Real 0…4294967000 - 1 = 1
10.102 RO2 toggle counter Real 0…4294967000 - 1 = 1
10.103 RO3 toggle counter Real 0…4294967000 - 1 = 1
11 Standard DIO, FI, FO
11.21 DI5 configuration List 0…1 - 1 = 1
11.38 Freq in 1 actual value Real 0…16000 Hz 1 = 1 Hz
11.39 Freq in 1 scaled value Real -32768.000…32767.000 - 1000 = 1
11.42 Freq in 1 min Real 0…16000 Hz 1 = 1 Hz
11.43 Freq in 1 max Real 0…16000 Hz 1 = 1 Hz
11.44 Freq in 1 at scaled min Real -32768.000…32767.000 - 1000 = 1
11.45 Freq in 1 at scaled max Real -32768.000…32767.000 - 1000 = 1
12 Standard AI
12.02 AI force selection PB 0b000...0b1111 - 1 = 1
12.03 AI supervision function List 0…4 - 1 = 1
12.04 AI supervision selection PB 0b000...0b1111 - 1 = 1
12.11 AI1 actual value Real 0.000…11.000 V V 1000 = 1 unit
12.12 AI1 scaled value Real -32768.000…32767.000 - 1000 = 1
12.13 AI1 forced value Real 0.000…11.000 V V 1000 = 1 unit
12.15 AI1 unit selection List 2, 10 - 1 = 1
12.16 AI1 filter time Real 0.000…30.000 s 1000 = 1 s
12.17 AI1 min Real 0.000…11.000 V V 1000 = 1 unit
12.18 AI1 max Real 0.000…11.000 V V 1000 = 1 unit
12.19 AI1 scaled at AI1 min Real -32768.000…32767.000 - 1000 = 1
12.20 AI1 scaled at AI1 max Real -32768.000…32767.000 - 1000 = 1
12.21 AI2 actual value Real 0.000…22.000 mA 1000 = 1 unit
12.22 AI2 scaled value Real -32768.000…32767.000 - 1000 = 1
12.23 AI2 forced value Real 0.000…22.000 mA 1000 = 1 unit
12.25 AI2 unit selection List 2, 10 - 1 = 1
12.26 AI2 filter time Real 0.000…30.000 s 1000 = 1 s
12.27 AI2 min Real 0.000…22.000 mA 1000 = 1 unit
12.28 AI2 max Real 0.000…22.000 mA 1000 = 1 unit
12.29 AI2 scaled at AI2 min Real -32768.000…32767.000 - 1000 = 1
12.30 AI2 scaled at AI2 max Real -32768.000…32767.000 - 1000 = 1
12.101 AI1 percent value Real 0.00…100.00 % 100 = 1%
12.102 AI2 percent value Real 0.00…100.00 % 100 = 1%
13 Standard AO
13.02 AO force selection PB 0b0000…0b1111 - 1 = 1
13.11 AO1 actual value Real 0.000…22.000 or
0.000…11000 V
mA 1000 = 1 mA
ACQ80 FW.book Page 185 Thursday, February 14, 2019 11:33 AM