88 Parameters
12.101 AI1 percent value Value of analog input AI1 in percent of AI1 scaling (12.18 AI1
max - 12.17 AI1 min).
100.00
0.00…100.00% AI1 value 100 = 1%
12.102 AI2 percent value Value of analog input AI2 in percent of AI2 scaling (12.28 AI2
max - 12.27 AI2 min).
0.00
0.00…100.00% AI2 value 100 = 1%
13
13 Standard AO
Configuration of standard analog outputs.
13.02 AO force selection The source signals of the analog outputs can be overridden
for eg. testing purposes. A forced value parameter is provided
for each analog output, and its value is applied whenever the
corresponding bit in this parameter is 1.
Note: Boot and power cycle reset the force selections
(parameters 13.02 and 13.11).
0b0000
0b0000…0b1111 Forced values selector for analog o utputs AO1 and AO2. 1 = 1
13.11 AO1 actual value Shows value of AO1 in mA
This parameter is read-only.
-
0.000…22.000 mA Value of AO1. 1 = 1 mA
13.12 AO1 source Selects a signal to be connected to analog output AO1. Output
frequency
Zero None. 0
Motor speed used 01.01 Motor speed used (page 67). 1
Output frequency 01.06 Output frequency (page 67). 3
Motor current 01.07 Motor current (page 67). 4
Motor current % of
motor nominal
01.08 Motor current % of motor nom (page 67). 5
Motor torque 01.10 Motor torque (page 67). 6
DC voltage 01.11 DC voltage (page 67). 7
Output power 01.14 Output power (page 68). 8
Speed ref used 12
Freq ref used 28.02 Frequency ref ramp output (page 101). 14
Process PID out 40.01 Process PID output actual (page 130). 16
Temp sensor 1
excitation
The output is used to feed an excitation current to the
temperature sensor 1, see parameter 35.11 Temperature 1
source. See also section Motor thermal protection (page 44).
20
Temp sensor 2
excitation
The output is used to feed an excitation current to the
temperature sensor 2, see parameter 35.21 Temperature 2
source. See also section Motor thermal protection (page 44).
21
Abs motor speed
used
01.61 Abs motor speed used (page 70). 26
Abs motor speed % 01.62 Abs motor speed % (page 70). 27
No. Name/Value Description Def/FbEq16
Bit Value
0 1 = Force AO1 to value of parameter 13.13 AO1 forced value. (0 = Normal mode)
1 1 = Force AO2 to value of parameter 13.23 AO2 forced value. (0 = Normal mode)
2…15 Reserved
ACQ80 FW.book Page 88 Thursday, February 14, 2019 11:33 AM