80 Parameters
10.24 RO1 source Selects a drive signal to be connected to relay output RO1. Ready run
Not energized Output is not energized. 0
Energized Output is energized. 1
Ready run Bit 1 of 06.11 Main status word (see page 75). 2
Enabled Bit 0 of 06.16 Drive status word 1 (see page 75). 4
Started Bit 5 of 06.16 Drive status word 1 (see page 75). 5
Magnetized Bit 1 of 06.17 Drive status word 2 (see page 76). 6
Running Bit 6 of 06.16 Drive status word 1 (see page 75). 7
Ready ref Bit 2 of 06.11 Main status word (see page 75). 8
At setpoint Bit 8 of 06.11 Main status word (see page 75). 9
Reverse Bit 2 of 06.19 Speed control status word (see page 77). 10
Zero speed Bit 0 of 06.19 Speed control status word (see page 77). 11
Above limit Bit 10 of 06.17 Drive status word 2 (see page 76). 12
Warning Bit 7 of 06.11 Main status word (see page 75). 13
Fault Bit 3 of 06.11 Main status word (see page 75). 14
Fault (-1) Inverted bit 3 of 06.11 Main status word (see page 75). 15
Fault/Warning Bit 3 of 06.11 Main status word OR bit 7 of 06.11
Main status
word (see page 75).
16
Overcurrent Fault 2310 Overcurrent has occurred. 17
Overvoltage Not applicable.
Drive temp Fault 2381 IGBT overload or 4110 Control board temperature
or 4210 IGBT overtemperature or 4290 Cooling or 42F1 IGBT
temperature or 4310 Excess temperature or 4380 Excess
temperature difference has occurred.
19
Undervoltage Fault 3220 DC link undervoltage has occurred. 20
Motor temp Fault 4981 External temperature 1 or 4982 External
temperature 2 has occurred.
21
Ext2 active Bit 11 of 06.16 Drive status word 1 (see page 75). 23
Remote control Bit 9 of 06.11 Main status word (see page 75). 24
Timed function 1 Not applicable.
Timed function 2 Not applicable.
Timed function 3 Not applicable.
Reserved 30...32
Supervision 1 Bit 0 of 32.01 Supervision status (see page 114). 33
Supervision 2 Bit 1 of 32.01 Supervision status (see page 114). 34
Supervision 3 Bit 2 of 32.01 Supervision status (see page 114). 35
Start delay Bit 13 of 06.17 Drive status word 2
(see page 76). 39
RO/DIO control
word bit0
Bit 0 of 10.99 RO/DIO control word (see page 82). 40
RO/DIO control
word bit1
Bit 1 of 10.99 RO/DIO control word (see page 82). 41
RO/DIO control
word bit2
Bit 2 of 10.99 RO/DIO control word (see page 82). 42
PFC1 Not applicable.