Actual signals and parameters
69
2203 DECELER TIME 1 Defines the deceleration time 1 i.e. the time required for the speed to change
from the value defined by parameter 2008 MAXIMUM FREQ to zero.
- If the speed reference decreases slower than the set deceleration rate, the
motor speed will follow the reference signal.
- If the reference changes faster than the set deceleration rate, the motor
speed will follow the deceleration rate.
- If the deceleration time is set too short, the drive will automatically prolong
the deceleration in order not to exceed drive operating limits.
If a short deceleration time is needed for a high inertia application, the drive
should be equipped a brake resistor.
5
0.0…1800.0 s Time