9908 MOTOR NOM SPEED Defines the nominal motor speed. Must be equal to the value on the motor
rating plate.
Type
dependent
50…30000 rpm Speed
9909 MOTOR NOM
POWER
Defines the nominal motor power. Must equal the value on the motor rating
plate.
P
N
0.2…3.0 · P
N
kW/hp Power
Parameters in the Long Parameter mode
Index Name/Selection Description Def

Table of Contents

Other manuals for ABB ACS150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS150 and is the answer not in the manual?

ABB ACS150 Specifications

General IconGeneral
Power Range0.37 to 4 kW
Voltage Range200 to 240 V, 380 to 480 V
Frequency50/60 Hz
Control MethodScalar control
Protection ClassIP20
Frequency Range0 to 500 Hz
Storage Temperature-40 to +70 °C
Relative Humidity5 to 95 % (non-condensing)
Ambient Temperature-10 to +50 °C
I/ODigital inputs, Analog inputs, Relay outputs
Overload Capacity150% for 60 seconds
Braking ChopperBuilt-in (for some models)