Actual signals and parameters
100
3404 OUTPUT1 DSP
FORM
Defines the format for the displayed signal selected by parameter 3401
SIGNAL1 PARAM.
9 = DIRECT
0 = +/-0 Signed/Unsigned value. Unit is selected by parameter 3405 OUTPUT 1
UNIT.
Example PI (3.14159):
1 = +/-0.0
2 = +/-0.00
3 = +/-0.000
4 = +0
5 = +0.0
6 = +0.00
7 = +0.000
8 = BAR METER Bar graph is not available for this application.
9 = DIRECT Direct value. Decimal point location and units of measure are identical to the
source signal.
Note: Parameters 3402, 3403 and 3405...3407 are not effective.
3405 OUTPUT1 UNIT Selects the unit for the displayed signal selected by parameter 3401
SIGNAL1 PARAM.
Note: Parameter is not effective if parameter 3404 OUTPUT1 DSP FORM
setting is DIRECT.
Note: Unit selection does not convert values.
-
0 = NO UNIT No unit selected
1 = A Ampere
2 = V Volt
3 = Hz Hertz
4 = % Percent
5 = s Second
6 = h Hour
7 = rpm Revolutions per minute
8 = kh Kilohour
9 = °C Celsius
11 = mA Milliampere
12 = mV Millivolt
3406 OUTPUT1 MIN Sets the minimum display value for the signal selected by parameter 3401
SIGNAL1 PARAM. See parameter 3402 SIGNAL1 MIN.
Note: Parameter is not effective if parameter 3404 OUTPUT1 DSP FORM
setting is DIRECT.
-
x…x Setting range depends on parameter 3401 setting. -
3407 OUTPUT1 MAX Sets the maximum display value for the signal selected by parameter 3401
SIGNAL1 PARAM. See parameter 3402 SIGNAL1 MIN.
Note: Parameter is not effective if parameter 3404 OUTPUT1 DSP FORM
setting is DIRECT.
-
x…x Setting range depends on parameter 3401 setting. -
Parameters in the Long Parameter mode
Index Name/Selection Description Def
3404 value Display Range
+/-0 +
3 -32768...+32767
+/-0.0 +
3.1
+/-0.00 +
3.14
+/-0.000 +
3.142
+0 3 0....65535
+0.0 3.1
+0.00 3.14
+0.000 3.142