No. Name/Value Description Def/FbEq16
Bit Name Information
0 Disable ABB access
levels
1 = ABB access levels (service, advanced programmer, etc.; see
96.03) disabled
1 Freeze parameter
lock state
1 = Changing the parameter lock state prevented, ie. pass code
358 has no effect
2 Disable file
download
1 = Loading of files to drive prevented. This applies to
• firmware upgrades
• safety functions module (FSO-xx) configuration
• parameter restore
• loading an adaptive program
• loading and debugging an application program
• changing home view of control panel
• editing drive texts
• editing the favorite parameters list on control panel
• configuration settings made through control panel such as
time/date formats and enabling/disabling clock display.
3 Disable FB write to
hidden
1 = Access to parameters on disabled access levels from fieldbus
prevented.
4…5 Reserved
6 Protect AP 1 = Creating a backup and restoring from a backup prevented.
7 Disable panel
Bluetooth
1 = Bluetooth disabled on ACS-AP-W control panel. If the drive is
part of a panel bus, Bluetooth is disabled on all panels.
8…10 Reserved
11 Disable OEM access
level 1
1 = OEM access level 1 disabled
12 Disable OEM access
level 2
1 = OEM access level 2 disabled
13 Disable OEM access
level 3
1 = OEM access level 3 disabled
14…15 Reserved