Parameters 307
99.09 Motor nominal
speed
Defines the nominal motor speed. The setting must match the
value on the rating plate of the motor.
Note: This parameter cannot be changed while the drive is
running.
0 rpm
0 … 6000 rpm Nominal speed of the motor. 1 = 1 rpm
99.10 Motor nominal
power
Defines the nominal motor power. The setting must match the
value on the rating plate of the motor. If nominal power is not
shown on the rating plate, nominal torque can be entered
instead in parameter 99.12.
If multiple motors are connected to the drive, enter the total
power of the motors.
Note: This parameter cannot be changed while the drive is
running.
0.00 kW
0.00 … 10000.00
kW
Nominal power of the motor. 1 = 1 unit
99.11 Motor nominal cos
Φ
Defines the cosphi of the motor for a more accurate motor
model. The value is not obligatory, but is useful with an
asynchronous motor, especially when performing a standstill
identification run. With a permanent magnet or synchronous
reluctance motor, this value is not needed.
Notes:
• Do not enter an estimated value. If you do not know the
exact value, leave the parameter at zero.
• This parameter cannot be changed while the drive is
running.
0.00
0.00 … 1.00 Cosphi of the motor. 100 = 1
99.12 Motor nominal
torque
Defines the nominal motor shaft torque. This value can be
given instead of nominal power (99.10) if shown on the rating
plate of the motor.
Notes:
• This setting is an alternative to the nominal power value
(99.10). If both are entered, 99.12 takes priority.
• This parameter cannot be changed while the drive is
running.
0.000
N·m
0.000 …
4000000.000
N·m
Nominal motor torque. 1 = 1 unit