Definitions
Supply voltage range
U
n
Nominal output current (available continuously with no over-loading)
I
N
Typical motor power in no-overload use
P
N
Continuous rms output current allowing 10% overload for 1 minute every 5 minutes
I
Ld
Continuous rms output current allowing 50% overload for 1 minute every 5 minutes.
I
Hd
* Continuous rms output current allowing 30% overload for 1 minute every 5 minutes.
** Continuous rms output current allowing 25% overload for 1 minute every 5 minutes.
Typical motor power in heavy-duty use
P
Hd
Note 1: The ratings apply at an ambient temperature of 40 °C (104 °F).
Output ratings with selection Low noise optimization of parameter
97.09 Switching freq mode
ACS880-01-…
Heavy-duty useLight-duty useNominal use
I
Hd
I
Ld
I
N
AAA
U
n
= 230 V
3.33.94.104A6-2
4.15.65.906A6-2
5.96.46.707A5-2
6.79.09.510A6-2
9.514.315.016A8-2
15.020.922.024A3-2
22.028.530.0031A-2
30.039.041.0046A-2
415356061A-2
475356075A-2
566467087A-2
678994115A-2
94112118145A-2
118139146170A-2
146169178206A-2
178205216274A-2
U
n
= 400 V
1.72.12.202A4-3
2.22.93.003A3-3
3.03.43.604A0-3
3.64.85.005A6-3
5.06.26.507A2-3
6.58.18.509A4-3
8.510.711.312A6-3
190 Technical data