Maintenance
OI/FEX300/FEX500-EN FEX300, FEX500 151
10.3.1 Transmitter
Warning – Electrical voltage risk!
When the housing is open, EMC protection is impaired and there is no longer any protection
against accidental contact.
Power to all connecting cables must be switched off.
Fig. 61
Replace the transmitter plug-in as follows:
1. Switch off supply power.
2. Open the housing cover (1).
3. Loosen screws (3) and pull out transmitter plug-in (2).
4. Replace transmitter plug-in and retighten screws (3).
5. Close the housing cover (1).
6. Downloading system data (see chapter 10.3.3 "Downloading the system data").