Functional and technical properties - HygienicMaster
166 FEX300, FEX500 OI/FEX300/FEX500-EN
Change from one to two colu mns
14.1.6 Material load
Limits for the permissible fluid temperature (TS) and permissible
pressure (PS) are calculated on the basis of the lining and flange
material used in the device (refer to the name plate on the device).
Process
connection
Nominal
diameter
PS
max
bar
(PSI)
TS
Wafer type DN 3 ... 50
(1/10 ... 2“)
40
(580)
-25 ... 130 °C
(-13 ... 266 °F)
DN 65 ... 100
(2 1/2 ... 4“)
16
(232)
Weld stubs DN 3 ... 40
(1/10 ... 1 1/2“)
40
(580)
-25 ... 130 °C
(-13 ... 266 °F)
DN 50, DN 80
(2“, 3“)
16
(232)
DN 65, DN 100
(2 1/2“, 4“)
10
(145)
Threaded pipe
connection
conforming to DIN
11851
DN 3 ... 40
(1/10 ... 1 1/2“)
40
(580)
-25 ... 130 °C
(-13 ... 266 °F)
DN 50, DN 80
(2“, 3“)
16
(232)
DN 65, DN 100
(2 1/2“, 4“)
10
(145)
Tri-Clamp
conforming to
DIN 32676
DN 3 ... 50
(1/10 ... 2“)
16
(232)
-25 ... 121 °C
(-13 ... 250 °F)
DN 65 ... 100
(2 1/2 ... 4“)
10
(145)
Tri-Clamp in acc.
with ASME BPE
DN 3 ... 100
(1/10 ... 4“)
10
(145)
-25 ... 130 °C
(-13 ... 266 °F)
External thread
ISO 228 / DIN 2999
DN 3 ... 25
(1/10 ... 1“)
16
(232)
-25 ... 130 °C
(-13 ... 266 °F)
OD tubing DN 3 ... 100
(1/10 ... 4“)
10
(145)
-25 ... 130 °C
(-13 ... 266 °F)
1/8" sanitary
connectors
DN 1 ... 2
(1/25 … 1/12“)
10
(145)
-10 ... 120 °C
(-14 ... 248 °F)
DIN flange stainless steel to DN 100 (4“)
G00215
PN 40
PN 25
PN 16
PN 10
0
5
10
15
20
25
30
35
40
45
-30 -10 10 30 50 70 90 110 130 150 170 190 [°C]
PS
[bar]
-22 14 50 86 122 158 194 230 266 302 338 374 [°F]
TS
0
72.5
145.0
217.5
290.0
362.5
435.0
507.5
580.0
652.5
PS
[psi]
Fig. 76
ASME flange, stainless steel, up to DN 100 (4”) (CL150 / 300)
G00216
PS
[bar]
TS
CL 300
CL 150
0
5
10
15
20
25
30
35
40
45
50
55
-30 -10 10 30 50 70 90 110 130 150 170 190 [°C]
-22 14 50 86 122 158 194 230 266 302 338 374 [°F]
PS
[psi]
72.5
145.0
217.5
290.0
362.5
435.0
507.5
580.0
652.5
725.5
797.5
0
Fig. 77
For CIP/SIP cleaning, higher temperatures are permitted for limited
time periods; refer to the table titled "Maximum permissible cleaning
temperature".
JIS 10K-B2210 flange
Nominal
diameter
Material PN TS PS [bar]
25 ... 100
(1 ... 4")
Stainless steel
10 -25 ... 180 °C
(-13 ... 356 °F)
10
(145 psi)
Wafer type design
Fig. 78
JIS 10K-B2210 wafer type design
Nominal
diameter
Material PN TS PS [bar]
DN 32 ... 100
(1 1/4 ... 4")
1.4404
1.4435
1.4301
10 -25 ... 130 °C
(-13 ... 266 °F)
10
(145 psi)