* The system loads the parameter memory in accordance with the selection made.
• The system restarts.
Condition 2.
The system does not start because of incorrect definition of one or more
individual system parameters or because the control system is not provided
with the equipment defined by the system parameters.
• The programming unit first presents one or more error messages on the upper line and a
menu for selection of changes of the parameter memory on the lower line.
• First correct any incorrect equipment settings.
513 MISPLACED I/O BOARD
• Then select a suitable alternative to correct any incorrectly defined system parameters:
a. Individual system parameters can be corrected with CHANGE. See further section 5.2.
Select ACTIVE in the succeeding menu to start up the system after the
incorrect equipment setting have been corrected.
b. Function button FR PROM as for condition a above.
c. Function button FR DISK as for condition b above.
• The system starts up.
INSTALLATION S3
5:67