Connections to service outlet and illumination.
Power supply to service outlet and illumination can be of three different types.
The outlet may be loaded with up to 100 VA when the control cabinet door is closed.
Service outlet and Illumination options
(431) (432)
(433)
200-600VAC
230/115 V
230 V
Only 380/230 VAC
3Ph + N
380-500
Optional trafo
230/115 V
Door Switch
g)
(406)
Optional
Earth Fault
Protection
(439)
Service Outlet (select one)
T 1 1 1
I I I l
i Q 'rf 4
Illumination 230 V
(421) (424) (422) (425)
(420)
The number in the parenthesis is option numbers.
Fig 6.14 Connections to service outlet and illumination 3.
Connection from main transformer.
The voltage is switched off with the mains switch on the front of the cabinet.
432 Connection in front of the mains switch without transformer. N.B. only for main voltage
380 V three-phase with (opt 153) neutral connection and service outlet for 230 V (opt 421,
422).
Cannot be combined with CEE intake (opt 132,133) since these intakes have no neutral
connection.
433 Connection in front of mains switch with transformer 380 V - 500 V (only together with opt
153 157) with secondary for 115 V and 230 V, 2 A. For both 432 and 433, the voltage is to be
switched off with an circuit breaker mounted in the upper section of the left-hand wall of
the cabinet. The circuit-breaker is approved in compliance with IEC.
Earth fault protection for service outlet (8)
439 For better personal safety, the service outlet can be fitted with an earth fault protection
that trips at 30 mA earth current. The earth protection is placed alongside the service
outlet.
Operating voltage 110 - 240 V AC